Monday, February 7, 2011

Placement of mezzanine adapters in full width blades

Folks,



I found this great article recently on one of the other UCS blogs. Its a great read and is worth looking when planning a fully redundant UCS installation.


http://www.unifiedcomputingblog.com/?p=170


UCSTECH

Palo vNIC or vHBA calculation

Folks,

I got this tip from a good friend at Cisco. It great information when you start to design a UCS system.

It is generally advertised in marketing materials that the M81K Palo card can do a maximum 56 virtual interfaces (vNICS and/or vHBAs) (sometimes 128 in some marketing materials). 

This limit is actually set on the number of uplinks from the chassis to the fabric interconnect.  The formula is (15n-4) where N is the number of uplinks.  So plugin 1, 2 or 4 to get your max.

1 uplink per FEX:   15*1-4 = 11
2 uplinks per FEX: 15*2-4 = 26
4 uplinks per FEX: 15*4-4 = 56 (hence the maximum in the marketing slide)



Thanks Jason,


UCSTECH